All articles
Research·10 min read·September 9, 2026

Three Papers Tried to Predict Touch From Video in August 2026. The 0.06 N Headline Only Holds On Their Own Glove.

EgoTac, EgoPHI and HOPE all landed in August 2026, all inferring hand force or pressure from egocentric video. EgoTac's contact IoU is 0.593 to 0.743 in domain and 0.178 to 0.285 out of it, and its own paper says an absolute newton error across sensors would need unsupported calibration assumptions. Of 158.9M frames across 19 egocentric hand datasets, 11.8% carry measured force.

Between 6 and 15 August 2026, three separate groups published models that predict hand force or pressure from ordinary egocentric video. The best in-domain number is an active-region force error of 0.056 N, from EgoTac (arXiv 2608.15060). That number was measured on the authors' own 264-sensor glove, and the same paper states that reporting an absolute newton error on any other sensor "would require unsupported cross-sensor calibration assumptions".

Held-out contact IoU for EgoTac runs 0.593 to 0.743 on datasets inside its training mix and 0.178 to 0.285 on the two it never saw. Same model, same metric, same task. The drop is 2.1x to 4.2x.

What landed in August 2026, and in what order

HOPE (arXiv 2608.06192, 6 Aug 2026, Seoul National University and RLWRLD) predicts per-vertex normal pressure and contact on a MANO hand mesh from monocular video, unifying tactile-glove, planar-sensor and contact-only annotations into one vertex space.

EgoPHI (arXiv 2608.13014, 13 Aug 2026, ETH Zurich) estimates dense contact maps and 3D force distributions on hand and object meshes from a single RGB image, supervised by physics simulation.

EgoTac (arXiv 2608.15060, 15 Aug 2026, Shanghai Qi Zhi Institute, SJTU, Tsinghua, Fudan) trains on a unified corpus of over 5.7M image-tactile pairs assembled from nine datasets, and is the only one of the three that reports a scaling analysis over data volume and source diversity.

They follow TouchAnything (arXiv 2605.13083, 13 May 2026), which released the EgoTouch capture set: 208 manipulation tasks, 1,891 episodes, roughly 2.1M frames, 16x16 pressure arrays per palm, plus dual wrist fisheye cameras to see past occlusion. Four vision-to-touch systems in four months is a real cluster, not a coincidence. The reason is economic: egocentric video is cheap and there is a lot of it, and measured force is neither.

The numbers, side by side, in the units each paper actually used

Nobody can rank these four systems, because no two of them report force in the same unit on the same sensor. EgoTac reports newtons per MANO vertex on its own glove. EgoPHI reports newtons per vertex of a 3D force distribution. HOPE reports kilopascals per vertex. TouchAnything reports a normalized MAE with no unit at all. That is the state of the field, stated plainly.

SystemDateIn-domain resultOut-of-domain resultForce unit reported OODSource
EgoTac15 Aug 2026MAE_act 0.056 N; contact IoU 0.743 (H2O), 0.669 (ARCTIC), 0.593 (HOT3D)contact IoU 0.285 (OAKINK2), 0.178 (FPHA)none; normalized [0,1] cosine >0.7 on OpenToucharXiv 2608.15060 Tables 2, 3, 4
EgoPHI13 Aug 2026hand force MAE 4.03 N, RMSE 5.06 N (ARCTIC); hand contact F1 0.190hand force MAE 5.16 N, RMSE 6.62 N (H2O); hand contact F1 0.097newtons, cross-dataset within simulation-derived labelsarXiv 2608.13014
HOPE6 Aug 2026OpenTouch vertex MAE 1.808 kPa, contact F1 0.660MOW in-the-wild contact F1 0.416; PressureVisionDB contact IoU 0.328, volume IoU 0.218kilopascalsarXiv 2608.06192
TouchAnything13 May 2026contact IoU 0.5030, volumetric IoU 0.4575, MAE 0.0436 (seen objects)contact IoU 0.4496, volumetric IoU 0.3852 (unseen objects)normalized, no unitarXiv 2605.13083
HACO (contact-only baseline)NeurIPS 2025not applicable, trained on 14 datasetscontact IoU 0.259 / F1 0.400 (OAKINK2); IoU 0.160 / F1 0.268 (FPHA)no force, binary contact onlyarXiv 2505.11152
The four 2026 vision-to-touch systems and the prior contact-only baseline. Every force unit in the table is different. Values transcribed from each paper's results tables, retrieved 9 September 2026.

How far does contact accuracy fall when the dataset changes?

EgoTac is the cleanest test because it reports the same metric on both sides. In-domain it holds a 9:1 split on datasets that are in the training mix (HOI4D, H2O, HOT3D, ARCTIC, TACO, plus its own EgoTac-SC). Out of domain it runs untouched on OAKINK2 and FPHA. The chart below is the whole story of vision-to-touch in one picture.

0.00.20.40.60.8 contact IoU 0.7430.6690.5930.2850.178 H2OARCTICHOT3DOAKINK2FPHA in training mix (held-out 10%) never seen (out of domain)
EgoTac contact IoU, from Tables 3 and 4 of arXiv 2608.15060. The three left bars are held-out splits of datasets in the training mix; the two right bars are datasets the model never saw.

EgoPHI shows the same shape from a different direction. Trained on ARCTIC alone, its hand contact F1 is 0.190 in distribution and 0.097 on H2O. That is a halving, and both numbers are low in absolute terms. TouchAnything degrades least of the three, from contact IoU 0.5030 to 0.4496, but its unseen split is unseen *objects* in the same rig and the same room, which is a much softer test than a different lab's dataset.

This is a judgement, not a measured claim: the ordering above suggests the difficulty ladder is objects, then scenes, then sensors, and only the third rung is the one that matters for buying data.

Why the newtons stop at the sensor boundary

The mechanism is calibration, and EgoTac spells it out. To test force transfer, the authors evaluate on OpenTouch, which uses different tactile hardware. Their own words: "The public OpenTouch annotations do not provide the per-taxel physical calibration and effective sensing areas required for a reliable conversion to Newton level forces. Therefore, a direct absolute-force MAE in Newtons would require unsupported cross-sensor calibration assumptions." So they normalize both prediction and ground truth to [0,1] and report cosine similarity above 0.7 and rise/fall F1 above 0.4 instead.

Read that as a supply statement rather than a modelling one. A newton is a physical unit, but a taxel reading is not, until somebody publishes the per-taxel calibration and the effective sensing area of the pad. Almost nobody does. The result is that a vision-to-touch model can only be scored in newtons on the exact hardware its ground truth came from, which means every group has to build a glove before it can claim a force number.

EgoTac-SC capture 264-sensor glove, 3.9M frames 24 environments, 70+ tasks EgoTac model trained on 5.7M image-tactile pairs Scored on the SAME glove MAE_act 0.056 N, temporal Pearson 0.506 Scored on OpenTouch (other glove) no newtons: normalized [0,1], cosine >0.7 Deployed on bare-hand video visual-domain gap, no ground truth at all the calibration wall: per-taxel calibration and effective sensing area are not published for other pads, so newtons do not cross it
Where the force ground truth comes from and where it stops. Solid arrow: the only path on which a newton figure is defensible. Dashed arrows: everything else.

There is a second gap in EgoTac's own limitations section, and it is the awkward one: "EgoTac-SC is collected with tactile gloves, introducing a visual-domain gap with bare-hand videos." The model whose purpose is to remove the need for gloves learned most of its force signal from footage of people wearing gloves.

How much measured force actually exists in the egocentric corpus?

We built the BLO LAB Vision-to-Touch Registry, covering the 19 egocentric hand-interaction datasets these four papers train and evaluate on, taking the properties table of arXiv 2608.15060 as the spine and adding EgoTouch. Total: 158.9M frames. Seven of the 19 carry measured force or pressure, and they account for 18.75M frames, 11.8% of the corpus. Narrow it to datasets that are both in-the-wild and force-measured, which is what a manipulation policy actually needs, and it is four datasets and 9.55M frames, 6.0%.

The concentration is the part worth staring at. Of that 9.55M in-the-wild force frames, 6.0M (63%) were captured during 2026 by two groups: EgoTac-SC at 3.9M and EgoTouch at 2.1M. Two years ago this category was OpenTouch's 550K frames and nothing else. The supply is small, recent, and concentrated in two labs.

No measured force (Ego4D, EgoDex, EPIC-KITCHENS, HOI4D, TACO, OakInk2, ARCTIC, H2O and 4 more) 140.1M frames Measured force or pressure (7 datasets) 18.75M (11.8%) Measured force AND in-the-wild (OpenTouch, FEEL, EgoTac-SC, EgoTouch) 9.55M (6.0%) 63% of it captured in 2026, by two groups
The BLO LAB Vision-to-Touch Registry: 19 datasets, 158.9M frames. Bars are to scale. Force is 11.8% of the corpus and in-the-wild force is 6.0%.
DatasetFramesContact labelMeasured forceForce hardwareEnvsIn the wild
EgoDex90MnoneNonot applicable1No
Ego4D (HOI)21MnoneNonot applicable900Yes
EPIC-KITCHENS11.5MnoneNonot applicable32Yes
TACO5.2MnoneNonot applicable1No
EgoPressure4.3MpressureYespressure-sensitive planar surface1No
OakInk24MnoneNonot applicable1No
EgoTac-SC3.9MpressureYescustom flexible glove, 264 force sensors24Yes
PressureVisionDB3.5MpressureYesinstrumented planar pressure surface1No
FEEL3MpressureYesforce-instrumented egocentric rig1Yes
HOI4D2.4MnoneNonot applicable610Yes
ARCTIC2.1ManalyticalNonot applicable1No
EgoTouch (TouchAnything)2.1MpressureYes16x16 pressure array per palm1Yes
HOT3D1.5MnoneNonot applicable4No
ActionSense1.4MpressureYesconductive-thread tactile glove1No
EgoPAT3D1.1MnoneNonot applicable15Yes
HO-Cap656KnoneNonot applicable1No
H2O571KanalyticalNonot applicable3No
OpenTouch550KpressureYesfull-hand tactile glove14Yes
FPHA105KnoneNonot applicable3No
19 egocentric hand-interaction datasets. Frame counts, contact-label type, environment counts and in-the-wild flags transcribed from Table 1 of arXiv 2608.15060, plus EgoTouch from arXiv 2605.13083. Retrieved 9 September 2026.

What this changes if you are buying or building manipulation data

Vision-to-touch does not remove the glove, it moves it upstream. Each of the four systems above needed a physically instrumented corpus before it could produce a number, and three of the four built new hardware to get one. The ceiling on how good these models get is the number of hours of real force capture in existence, and that is 7 datasets and 18.75M frames.

Treat any in-domain force figure as a sensor spec, not a model result. 0.056 N is what EgoTac achieves against the ground truth of the glove it trained on. It says the model has learned that glove. It does not say what the error would be on your gripper, and the paper is explicit that the conversion is not available.

If you publish tactile data, publish the calibration. Per-taxel calibration and effective sensing area are what EgoTac says are missing from OpenTouch, and their absence is why the whole field is stuck reporting normalized correlations. This is cheap to fix and nobody is fixing it. A dataset that ships a calibration table is worth more than one twice its size that does not.

Contact is not force, and most of the reported wins are contact. Out-of-domain evaluation in all three August papers is dominated by binary contact metrics, because that is what the public reference datasets provide. Binary contact tells a policy where the hand touched. It does not tell it whether the grip was 2 N or 20 N, which is the difference between holding an egg and breaking it.

That is the same conclusion this lab reached from the other direction in The Egocentric Data Wave, and it needs one honest amendment. A camera can now say something useful about the newtons at the fingertip, on the sensor it was trained against. It still cannot say it anywhere else.

Check it yourself

Every number above is in a table in a public preprint. Pull them:

``` curl -sL https://arxiv.org/pdf/2608.15060 -o egotac.pdf python3 -c "import pypdf;print('\n'.join(p.extract_text() for p in pypdf.PdfReader('egotac.pdf').pages))" > egotac.txt grep -A 20 'Table 1:' egotac.txt # the real-force column, 18 datasets grep -A 8 'Table 2:' egotac.txt # MAE 0.004, MAE_act 0.056 N, Pearson 0.506 grep -A 12 'Table 3:' egotac.txt # in-domain contact IoU 0.593 to 0.743 grep -A 14 'Table 4:' egotac.txt # out-of-domain contact IoU 0.178 and 0.285 grep -B 2 -A 4 'cross-sensor calibration' egotac.txt ```

The calibration sentence is in section 5.3, "OOD force-sensitive benchmark on OpenTouch". The glove-versus-bare-hand admission is in Appendix H, "Limitations". For the other two papers, arXiv 2608.13014 reports EgoPHI's ARCTIC and H2O force tables, and arXiv 2608.06192 reports HOPE's OpenTouch, PressureVisionDB and MOW tables. To reproduce the corpus arithmetic, sum the frame column of Table 1 and split it on the Real Force column: 140.132M without, 18.75M with, once EgoTouch's 2.1M is added from arXiv 2605.13083.

What would prove this wrong

A falsifiable prediction, dated. By 1 March 2027, no vision-to-touch paper will report an absolute newton force error on a dataset its authors did not help collect. Normalized correlations, kilopascals on a matched pad, and binary contact metrics do not count. What would falsify it is a paper that publishes per-taxel calibration and effective sensing area for two different tactile pads, converts both to newtons, and reports cross-sensor MAE in that unit.

A weaker version to watch on the same date: if any of these models gets out-of-domain contact IoU above 0.45 on both OAKINK2 and FPHA, the transfer problem is smaller than this article claims and the difficulty ladder above is wrong. Today the best published figures are 0.285 and 0.178.

Sources

Work with us

Building or training robots?

We license manipulation datasets and run custom capture programs. Get in touch to see what fits.