All articles
Research·10 min read·September 10, 2026

The LeRobot Corpus Runs at 30 Hz. Its Only Newtons Run at 10, Because the Format Has One Clock.

Reading fps from 261 LeRobot schemas on 10 September 2026: 177 of them are exactly 30 Hz, 245 are at or below 50 Hz, and two reach 250 Hz. The three RH20T ports are the only datasets in the sample carrying a named six-axis wrench, and they declare 10 Hz, matching RH20T's camera rate rather than the 100 Hz its own specification gives for the force/torque sensor. LeRobot v3 supports a per-feature fps, 37 of 261 datasets set it, and not one sets two different values.

On 10 September 2026 we read the `fps` field from `meta/info.json` for the 261 readable LeRobot repositories among the top 300 by downloads on Hugging Face. 177 of them, 67.8%, declare exactly 30 Hz. 245 of 261, 93.9%, are at or below 50 Hz. Two datasets reach 250 Hz and neither carries a contact channel.

The three `robot-lev/rh20t_cfg*` ports are the only datasets in the sample with a named six-axis wrench. They declare 10 Hz. RH20T's own data specification lists its cameras at 10 Hz and its force/torque sensors at 100 Hz. The port ships the force at the camera rate, a factor of ten below the rate the original capture rig ran it at.

One clock per dataset, set by the slowest thing in it

LeRobotDataset stores a single global `fps` in `meta/info.json`, and every row of the Parquet shard is one frame at that rate. The v3.0 schema does allow an optional per-feature `fps` inside a feature entry, which would let a wrench run faster than the video. We checked all 261: 37 datasets populate a per-feature `fps` on at least one feature, and zero of them declare more than one distinct value. `lerobot/aloha_mobile_cabinet` sets `"fps": 50` on `observation.effort`, which is the same 50 Hz as the dataset global.

So in practice the corpus has exactly one sampling rate per dataset, and the rate is set by whatever the recording rig could sustain for video. Every proprioceptive and contact channel is resampled onto that grid on the way in.

That is a reasonable default for joint angles, which are smooth. It is the wrong default for contact, which is not.

Declared fpsDatasetsShare of datasetsFramesShare of framesContact channel present?
3 Hz10.4%3,786,4000.26%no
5 Hz93.4%13,809,3760.96%no
10 Hz238.8%63,581,9284.42%yes, all three RH20T ports
15 Hz186.9%260,451,67318.12%no
20 Hz135.0%239,890,11516.69%no
25 Hz20.8%1,322,1420.09%yes, sii-rhos-ai/vifailback
29 Hz20.8%5,598,4830.39%no
30 Hz17767.8%835,286,21358.11%yes, trex_dataset and ego-tactile
50 Hz135.0%605,2610.04%yes, lerobot/aloha_mobile_cabinet
80 Hz10.4%204,8060.01%no
250 Hz20.8%12,917,5530.90%no
Total261100%1,437,453,950100%7 datasets
Sampling rate census of the 261 readable LeRobot schemas in the top 300 by downloads, Hugging Face Hub, 10 September 2026. Read from the fps field of meta/info.json.

The distribution is not a spread, it is a spike. Two thirds of the corpus sits on one value, and that value is the frame rate of a webcam.

Declared fps across 261 LeRobot datasets, 10 Sep 2026 18013590450 1923181322 1771312 351015202529305080250 declared fps (categorical, not to scale) y axis: number of datasets. 30 Hz is 67.8% of the corpus; only 2 datasets exceed 80 Hz and neither records contact.
Two thirds of the readable LeRobot corpus declares 30 Hz. Sixteen datasets exceed it, two by a meaningful margin, and none of those two record force.

What gets thrown away between 100 Hz and 10 Hz

RH20T was built by Fang et al. at SJTU and posted on 2 July 2023 as a contact-rich corpus, over 110,000 sequences across 147 tasks and seven robot configurations. Its published data specification runs the RGB, depth and IR streams at 10 Hz and the six-axis force/torque sensors at 100 Hz. Those are the original authors' own choices, and the 10x split between them is the closest thing the field has to a stated estimate of how much faster contact needs to be sampled than vision.

The LeRobot port declares `fps: 10` and 2,212,776 frames for cfg1, 1,272,711 for cfg4 and 443,540 for cfg3. Every row is one camera frame, and the wrench is one value on that row. The port does not state whether the 100 Hz stream was decimated to every tenth sample or averaged into 100 ms bins, and we could not determine it from the metadata alone. The two choices fail differently: decimation aliases high-frequency content down into the band you keep, averaging attenuates it. Neither recovers it.

The physics is not in dispute even if the exact numbers for a given task are. A 10 Hz grid puts the Nyquist limit at 5 Hz, so anything in the wrench that oscillates or steps faster than five times a second cannot be represented. Impact transients, stick-slip chatter and the moment a grasp starts to fail all live above that. This is a judgement about which frequencies matter, marked as one, but the sampling limit itself is arithmetic.

RH20T capture rig, then the LeRobot port as captured (RH20T specification) force / torque sensor, 100 Hz RGB / depth / IR cameras, 10 Hz meta/info.json "fps": 10 one wrench per camera frame Nyquist limit 5 Hz Samples per second of force in the source: 100. In the published LeRobot rows: 10. source, 100 Hz published, 10 Hz 9 of every 10 force samples are not in the file
The port pins a 100 Hz wrench to a 10 Hz camera clock. The format has a per-feature fps that would avoid this, and no dataset in the top 300 uses it to run two different rates.

The escape hatch exists and sits unused. LeRobot v3 lets a feature carry its own `fps`, which is the one line of metadata that would let a wrench run at 500 Hz alongside 30 Hz video in the same repository. Across the 261 readable schemas, 37 set it and every one of those 37 sets it to the dataset global.

Use of the per-feature clock across 261 LeRobot schemas 224 no per-feature fps every channel on the global clock 37 per-feature fps declared value equals the global, every time 0 two or more distinct rates the multi-rate path is untested The format can carry a fast force channel next to slow video. Nothing in the top 300 does. Read from the fps key inside each feature entry of meta/info.json, 10 September 2026.
The multi-rate path is available and unexercised. 37 datasets set a per-feature clock and all 37 set it to the value it already had.

What this means if you are recording or training

If you are building a capture rig, do not set your force rate from your camera rate. They are different physical problems and LeRobot v3 already lets you declare them separately, with a per-feature `fps` on the feature entry. The corpus shows nobody exercising that, which means the path is untested rather than unavailable, and someone has to be first.

If you are training on `robot-lev/rh20t_cfg*` because it is the only newtons in the corpus, know that you are training on the low-frequency envelope of a wrench, not on the wrench. Policies learned from it can plausibly regress steady contact load. Expecting them to catch a slip onset is expecting information that is not in the file.

If you are evaluating a dataset before licensing or downloading it, read `fps` first and the modality list second. A 30 Hz recording with a tactile array is a 30 Hz tactile array, whatever the sensor datasheet claims, and `zekaiwang/trex_dataset` at 30 Hz and `OpenGraphLabs-Research/ego-tactile-manipulation` at 30 Hz are both in that position.

The two fastest datasets in the corpus, `mickeykang/dvla-place7obj-roll-250hz-events-250fps-delta-trim` at 250 Hz with 11,561,473 frames and `mickeykang/dvla-can-250hz-events-250fps-delta-trim` at 250 Hz with 1,356,080, prove the format can carry high-rate data. Both are Franka Panda datasets whose non-image features are `action` [10], `observation.state` [9] and `observation.environment_state` [9]. Neither records force. High rate and contact do not currently coexist anywhere in the top 300.

Check it yourself

The whole census is one field. Fetch any schema and print it:

``` curl -sL https://huggingface.co/datasets/robot-lev/rh20t_cfg1/resolve/main/meta/info.json \ | python3 -c "import json,sys; i=json.load(sys.stdin); print('fps', i['fps'], 'frames', i['total_frames'])" ```

That prints `fps 10 frames 2212776`. To reproduce the histogram, list the corpus and loop:

``` for s in 0 100 200; do curl -sL "https://huggingface.co/api/datasets?filter=LeRobot&sort=downloads&direction=-1&limit=100&skip=$s" done | python3 -c "import json,sys; [print(x['id']) for l in sys.stdin for x in json.loads(l)]" ```

Then fetch `meta/info.json` for each id and tally `fps`. Our tally: 261 readable, 39 unreadable (30 gated with HTTP 401, 9 missing with HTTP 404), median 30 Hz, 177 datasets at exactly 30 Hz, 16 at or above 50 Hz, 2 at or above 100 Hz.

For the per-feature clock, check whether any feature entry carries its own `fps` and whether the values differ:

``` curl -sL https://huggingface.co/datasets/lerobot/aloha_mobile_cabinet/resolve/main/meta/info.json \ | python3 -c "import json,sys; i=json.load(sys.stdin); print({k: v.get('fps') for k,v in i['features'].items() if isinstance(v,dict) and 'fps' in v})" ```

Every value it prints is 50, matching the dataset global. Across all 261 repositories, 37 declare a per-feature `fps` and the number declaring two distinct values is zero.

RH20T's own rates are on the project page under the data specification table: cameras 10 Hz, force/torque 100 Hz.

What would prove this wrong

A dated prediction: re-run the fps census on 10 March 2027 and the median declared fps of the top 300 LeRobot datasets by downloads will still be 30, and the number of datasets declaring two or more distinct per-feature rates will be fewer than five.

The disproof is specific and easy to spot: a dataset on the Hub with `"fps": 30` at the top level and a contact feature carrying its own `"fps": 200` or higher, holding more than 100,000 episodes. That would show the multi-rate path works in practice, and it would make the resampling argument here a historical note.

One caveat that would change the measurement rather than the claim. If a future LeRobot version moves rate declaration out of `info.json`, our one-field census stops being the right instrument and the number would need to be recomputed from wherever the rate then lives.

Sources

All fps values, frame counts and per-feature clock checks were read from `meta/info.json` files fetched on 10 September 2026. RH20T's capture rates come from the project's published data specification.

Work with us

Building or training robots?

We license manipulation datasets and run custom capture programs. Get in touch to see what fits.