All articles
Research·12 min read·September 21, 2026

The Force Profile Came From Generated Audio. Every Newton in It Came From a Hand-Set 15 N Cap.

A pipeline from Penn's GRASP Lab derives contact-force profiles from the loudness of audio generated alongside a robot video, and lifts zero-shot success on four contact-rich tasks from 8 of 40 to 36 of 40. Read the equations and the audio sets only a normalised shape inside a range a human picked: F_max is 15 N for every task, F_min is a quarter of that. Against a constant setpoint, the generated shape is worth two trials in ten.

The force-aware pipeline succeeded in 36 of 40 zero-shot real-robot trials against 8 of 40 for the kinematic-only baseline, across whiteboard wiping, carrot peeling, chocolate box stacking and lamp button pressing. The paper is Dreaming the Sound of Contact, arXiv:2609.19137, posted 16 September 2026 by Guanhua Ji, Tianyu Li, Dayoon Suh, Yuqian Zhang, Boyan Zhang and Nadia Figueroa at the GRASP Lab, University of Pennsylvania.

The generated audio contributes a shape and nothing else. Loudness in LUFS is converted to a ratio and min-max normalised into a range whose upper bound, F_max = 15 N, is a single hand-picked constant used for all four tasks, and whose lower bound is defined as a quarter of it. The paper states this directly in Section III-B-4. So the pipeline's newtons are not inferred from anything generative; a human chose 15 N because the Franka's default collision threshold is 20 N and that leaves a margin.

Two branches, and only one of them touches the force magnitude

The video branch does the geometry. MolmoPoint places a point on each of the two contacting entities in frame 0, SAM 2 propagates masks, TAPIP3D recovers depth and 3D tracks, and the predicted depth is calibrated against the real sensor's frame-0 depth with a single global scale and offset fitted by RANSAC. Per-frame rigid fits over the gripper points give a relative transform in the camera frame, which is conjugated into the base frame and then applied as a delta on the robot's measured initial pose rather than as an absolute reconstruction. That last choice is what keeps millimetre errors in the generated video from becoming millimetre errors at the workpiece.

The audio branch does the profile. SAM-Audio isolates the contact sound with a shared text prompt, per-frame loudness is computed in LUFS, frames below -65 LUFS are treated as noise and assigned zero force, and the remainder are mapped through r = 2 raised to LUFS over 10, the psychoacoustic doubling rule, then min-max normalised into [F_min, F_max]. A separate geometric gate zeroes the force whenever the nearest-neighbour distance between gripper and object point clouds exceeds 0.03 m.

Execution closes the loop on the robot, not on the audio. A Cartesian impedance controller runs at 1 kHz with fixed translational stiffness 2000 N/m, and a regulator at 50 Hz integrates a normalised force error into a virtual-target displacement along the contact direction, with integrator gain 0.0003 and a short-horizon lookahead to anticipate overshoot. No audio is recorded or processed at execution time. The measured force comes from the Franka's own joint-torque estimate.

Where each number in the force-aware trajectory comes from (arXiv:2609.19137) Seedance 2.0 generates video and synchronised audio from one RGB frame and a task prompt. VIDEO BRANCH, sets the motion AUDIO BRANCH, sets only the shape MolmoPoint + SAM 2 point prompt, mask propagated SAM-Audio isolates contact sound prompt: sound of contact between gripper and object TAPIP3D 3D point tracks depth calibrated z = a*z_pred + b, RANSAC on frame 0 Per-frame loudness in LUFS discard below -65 LUFS, ITU-R BS.1770-4 with margin Rigid fit per frame relative SE(3), applied as a delta on the measured pose r = 2^(LUFS/10), then min-max normalised into [3.75 N, 15.00 N] F_max = 15 N, hand-set, identical for all 4 tasks F_min = 0.25 * F_max. The audio never sets a level. Contact gate: nearest-neighbour distance below d_th = 0.03 m, else force is zero Franka Panda, Cartesian impedance at 1 kHz, k = 2000 N/m, k_r = 150 N m/rad Force regulator at 50 Hz drives a virtual-target displacement; K_I = 0.0003. Protective stop at 20 N counts as a failure. No audio is recorded or processed during execution. The loop closes on the Franka's own joint-torque force estimate.
Every quantity in the executed trajectory, and which branch produced it.

What the 36 of 40 headline is actually comparing

The kinematic-only baseline executes the same extracted trajectories with the desired contact force set to zero throughout, which means no force regulation at all. So the 36 of 40 against 8 of 40 measures closed-loop force regulation against open-loop replay. It does not measure generated audio against anything. The failure modes confirm it: every wiping and pressing failure in the baseline was the end effector passing a few millimetres above the surface, and every peeling and stacking failure was excessive contact.

The comparison that isolates the audio is the profile ablation, and it is much narrower.

TaskForce profileSuccessMean peak (N)Mean impulse (N s)Source
Whiteboard wipingAudio-shaped, F_max = 10 N7 / 109.31 +/- 1.4315.20 +/- 4.42arXiv:2609.19137 Table II
Whiteboard wipingAudio-shaped, F_max = 15 N10 / 1012.38 +/- 1.1321.50 +/- 3.32arXiv:2609.19137 Table II
Whiteboard wipingConstant 10 N8 / 1012.86 +/- 0.4525.71 +/- 5.11arXiv:2609.19137 Table II
Whiteboard wipingConstant 15 N2 / 1015.36 +/- 0.3030.28 +/- 6.32arXiv:2609.19137 Table II
Carrot peelingAudio-shaped, F_max = 10 N9 / 108.76 +/- 1.6518.34 +/- 5.16arXiv:2609.19137 Table II
Carrot peelingAudio-shaped, F_max = 15 N9 / 1011.39 +/- 1.5227.88 +/- 9.74arXiv:2609.19137 Table II
Carrot peelingConstant 10 N8 / 1012.98 +/- 1.4239.16 +/- 11.13arXiv:2609.19137 Table II
Carrot peelingConstant 15 N6 / 1014.79 +/- 0.93106.42 +/- 61.97arXiv:2609.19137 Table II
Peak force and impulse are mean and standard deviation over all 10 trials including failures, evaluated over the commanded-force interval. Ten real-robot trials per task-condition pair.

Two trials in ten on wiping, one in ten on peeling, against the best constant profile. That is the measured value of the generated loudness signal in this experiment. The paper is candid about why: both tasks tolerate a range of contact forces, so the role of the profile is to stay inside the feasible range and to enter contact gradually, rather than to track a specific force.

The failure mechanism for the constant conditions is a step. When the desired force jumps from 0 N to the setpoint at first contact, the robot tries to track the step, the measured force can overshoot to the 20 N safety limit, and the protective stop counts as a failure. The audio-shaped profile rises smoothly after contact and does not produce that failure. Which leaves an obvious missing control: a constant setpoint with a linear ramp at contact onset. It is not in the paper.

What the generated audio is worth against a constant setpoint, on the two sustained-contact tasks Successes out of 10 real-robot trials per task-condition pair. Mean peak force printed above each bar. 0 2 4 6 8 10 successes / 10 7 10 8 2 Whiteboard wiping 9 9 8 6 Carrot peeling 9.3 N 12.4 N 12.9 N 15.4 N 8.8 N 11.4 N 13.0 N 14.8 N Audio-shaped, F_max = 10 N Audio-shaped, F_max = 15 N Constant 10 N Constant 15 N Against the best constant profile, the audio-shaped one is worth 2 trials in 10 on wiping and 1 in 10 on peeling. The baseline the paper does not run: a constant setpoint with a ramp at contact onset.
The only comparison in the paper that isolates the generated audio. Peak force in newtons above each bar.

The prompt-ordering test, and what it does not establish

The authors run a controlled hammer experiment to check whether generated loudness tracks prompted force. From one image of a hand holding a hammer, Seedance 2.0 is asked to strike the table twice, first with F1 then with F2, using (5 N, 20 N) and (20 N, 5 N). Ten videos per order. Impact loudness is measured in LUFS over a 400 ms window around each detected contact, and a trial is order-consistent when the 20 N strike is louder. The result is 18 of 20, 9 of 10 in each direction.

The paper's own framing of that number is the correct one and worth repeating: it tests whether the generator follows a prompted force order, not whether loudness measures physical contact force. A model that reliably renders the word twenty as louder than the word five has demonstrated prompt adherence. It has not demonstrated a calibration.

There is a screening caveat too. For wiping, peeling and pressing, every generated video goes straight to segmentation with no manual selection. For chocolate box stacking, 20 videos were generated and 10 discarded because the gripper grasped the box from the sides instead of sliding under it, or the end effector flipped. That task's 9 of 10 sits on top of a 50% rejection rate at the generation stage, and the rejection is a human judgement about grasp feasibility.

Abstract technical rendering of an audio waveform envelope being compressed into a narrow horizontal band bounded above and below by two fixed horizontal lines.
The whole of the audio contribution: a per-frame loudness curve in LUFS, thresholded at -65, converted by r = 2 to the power LUFS over 10, then min-max normalised into a band from 3.75 N to 15.00 N. Both bounds are set by one hand-chosen constant that is the same for all four tasks. Any monotone loudness curve with the same shape produces the same commanded forces.

As a data-generation engine, the force labels behave oddly

The second half of the paper uses the pipeline to manufacture training data: 50 force-aware rollouts per task that meet the success criterion, each logging end-effector pose, force profile and two RGB views. A CNN diffusion policy trained on those demonstrations, with no force input, scores 29 of 40 across the four tasks at previously unseen object positions and with appearance variation. A second policy that additionally observes the Franka's 3D contact force scores 34 of 40.

The interesting part is what happens to force impulse rather than to success. On wiping, adding the force input cuts mean impulse from 89.94 to 22.03 N s. On peeling it raises it from 100.82 to 137.11 N s, and raises mean peak force from 6.76 N to 10.20 N, while lifting success from 8 of 10 to 10 of 10. So the force channel is not uniformly a gentleness channel here; on peeling the policy needed to press harder and the force observation is what let it. That is the opposite sign to the glove result published four days earlier, where the same kind of channel halved applied force on a grasp-and-hold, and the difference is that peeling has a force floor below which the task fails.

One more detail worth carrying: the no-force policy commands poses only, so its contact force arises entirely from the penetration depth it reproduces from the demonstrations, and even so it follows the demonstration force within roughly 2 N on wiping, pressing and stacking. On a task with a fixed-stiffness impedance controller, position labels carry a force signal implicitly. Peeling is the exception, where both policies press harder than the demonstrations.

TaskPolicySuccessMean peak (N)Mean impulse (N s)Source
WipingDiffusion policy, no force input8 / 109.14 +/- 0.4089.94 +/- 25.20arXiv:2609.19137 Table III
WipingDiffusion policy, force input9 / 109.69 +/- 1.6822.03 +/- 13.94arXiv:2609.19137 Table III
PeelingDiffusion policy, no force input8 / 106.76 +/- 1.00100.82 +/- 37.74arXiv:2609.19137 Table III
PeelingDiffusion policy, force input10 / 1010.20 +/- 1.14137.11 +/- 39.89arXiv:2609.19137 Table III
StackingDiffusion policy, no force input8 / 106.58 +/- 0.959.88 +/- 4.25arXiv:2609.19137 Table III
StackingDiffusion policy, force input8 / 106.75 +/- 1.698.79 +/- 3.87arXiv:2609.19137 Table III
PressingDiffusion policy, no force input5 / 109.08 +/- 1.288.71 +/- 4.60arXiv:2609.19137 Table III
PressingDiffusion policy, force input7 / 108.91 +/- 1.565.33 +/- 2.91arXiv:2609.19137 Table III
Peak and impulse are means over successful rollouts only, evaluated over the task-relevant contact interval, so they are not directly comparable with Table II, which includes failures. Ten trials per policy at unseen positions.

What this means if you are deciding whether to buy force capture

A generated force channel and a measured one are not substitutes, and this paper is the cleanest statement of why. What the pipeline supplies is a temporal shape with a sensible onset, bounded by a number a human typed. What it cannot supply is the level, and on the two tasks where the level was varied the level changed success by 8 trials in 10, from 10 of 10 at an audio-shaped 15 N cap to 2 of 10 at a constant 15 N. The cap and the ramp are doing the work.

That is still useful, and cheap. If your task tolerates a range of forces, which wiping and peeling both do, a generated ramp inside a hand-set safety bound gets you a working demonstration set with no teleoperation and no force-instrumented hardware. The Dreaming Contact Dataset is released across those four tasks.

It stops being useful the moment the task has a narrow force window, and nothing in the pipeline can tell you where that window is. Peeling needed roughly 10 N of peak force to succeed and wiping needed roughly 12 N; both numbers came out of the execution, measured by the robot's joint torques, not out of the generator. Our judgement: treat a generated force profile as a scheduling prior and the measured trace from execution as the actual label, and sell the second one.

The recording is worth more than the generation for a second reason. Every rollout here produced a real measured force trace from a real impedance controller on a real Franka. Forty zero-shot trials and 200 retained demonstrations later, the asset that exists is a set of measured contact traces paired with poses and two camera views. That is a force-annotated corpus that did not require a human operator, which is the actual news.

Check it yourself

The claim that the audio sets no level is checkable in one paragraph of the paper. Pull Section III-B-4 and read the sentence after equation 7:

curl -s https://arxiv.org/html/2609.19137v1 | python3 -c 'import sys,re,html; t=re.sub(r"<[^>]+>"," ",sys.stdin.read()); print(html.unescape(re.sub(r"\s+"," ",t)))' | grep -o 'The audio thus determines.\{0,300\}'

The pipeline, the prompts and the first version of the Dreaming Contact Dataset are at dreamingcontactsound.github.io. Every component below the generator is public: MolmoPoint, SAM 2, TAPIP3D and SAM-Audio, with the generator being Seedance 2.0.

If you want to test the missing baseline yourself, you do not need the generator at all. Take any extracted kinematic trajectory, command a constant 10 N with a linear ramp over the first 0.5 s of the contact interval, and run it through the same 1 kHz impedance controller at k = 2000 N/m with a 50 Hz regulator. The failure the paper attributes to the step should disappear, and the question becomes whether the audio-shaped profile still wins.

One measurement discipline worth copying: Table II reports peak and impulse over all 10 trials including failures, while Table III reports them over successful rollouts only. Mixing those two conventions across a comparison would invent a difference that is not there.

What would prove this wrong

Our reading is that the generated loudness is worth a gradual onset and little else on these tasks, and that a ramped constant setpoint would recover most of the benefit. The authors' own mechanism section supports it: they attribute the constant-profile failures specifically to the step at first contact.

Falsifiable, with a date: by 31 March 2027, if anyone runs whiteboard wiping and carrot peeling on the same setup with a constant 10 N profile that ramps linearly over the contact-onset window, and it reaches 10 of 10 and 9 of 10 with peak force and impulse within 10% of the audio-shaped F_max = 15 N rows, then the generated audio adds nothing a two-line ramp does not, and the pipeline's contribution is the closed-loop regulator plus a safety cap. If the ramped constant still loses by two or more trials on either task, the loudness curve is carrying task-specific structure and we are wrong.

A second test, on the stronger claim. The hammer experiment establishes prompt adherence, not calibration. Prompt the same generator for the same task at 5 N and at 15 N, run both resulting profiles through the regulator, and measure the executed peak force. If the two executions separate by less than 2 N, then prompted force magnitude does not survive into the robot and the cap is the only thing setting the level, which is what we expect from equation 7.

Sources

Work with us

Building or training robots?

We license manipulation datasets and run custom capture programs. Get in touch to see what fits.