Recording a Teleoperator's Real Eye Gaze, Then Using It Only to Regularize Training, Lifts Real-Robot Success From 48.1% to 58.6% Across 18 Tasks. Pushing the Gaze Signal Too Hard Drops Performance Below the No-Gaze Baseline.
GazeAct (arXiv:2610.24507, University of Hong Kong, submitted 17 October 2026) records a teleoperator's screen-based eye gaze at 300 Hz on 12,000 demonstrations across 40 tasks and five domains, then uses it as a training-only regularizer for vision-language-action policies. Real-world success rises from 48.1% to 58.6% on average across 18 tasks, transfers to a second backbone (OpenVLA, 45.2% to 55.7%) and to simulation (LIBERO-Spatial, 57.9% to 69.6%), but an ablation shows the gain depends on treating gaze as a soft prior: the strongest regularization weight tested scores 38.0%, below the 59.5% no-gaze baseline on the same six-task subset.
GazeAct records a teleoperator's actual eye gaze during data collection, at 300 Hz, and uses it only to regularize where a robot policy attends during training, never as an input at inference (arXiv:2610.24507, Anupam Pani, Wang Yuan, Qifan Wang and Yanchao Yang, HKU Musketeers Foundation Institute of Data Science and the Department of Electrical and Electronic Engineering, University of Hong Kong, submitted 17 October 2026). Across 18 real-world tasks at 100 trials each, average success rises from 48.1% to 58.6%, a 10.5-point gain, with individual tasks ranging from a 3-point gain to a 25-point gain.
The same gaze signal transfers across backbones (OpenVLA rises from 45.2% to 55.7% on six tasks) and into simulation (LIBERO-Spatial rises from 57.9% to 69.6%). But an ablation on regularization strength shows the effect depends on treating gaze as a loose nudge rather than a hard target: the heaviest weighting tested scores 38.0% on a six-task subset, below the 59.5% no-gaze baseline on those same six tasks.
What changed: gaze recorded in the robot's own camera view, not a lab rig
Earlier gaze-robotics datasets, including HARMONIC (480 demonstrations, one task, 120 Hz) and the DAA driving-attention dataset (224,210 demonstrations, 11 tasks, 120 Hz), record gaze at high frequency but outside a manipulation-robot's actual camera stream, which leaves a mismatch between where the gaze was measured and what the policy will actually see. GazeAct's operators teleoperate through a screen showing the robot's own camera feed, with an eye tracker reading gaze on that same screen, so the recorded fixation point is already in the robot's observation space. The paper then geometrically transfers that fixation point to every other synchronized camera view the robot carries, so a single-view gaze reading becomes a spatially consistent attention target across all of them.
GazeAct totals 12,000 demonstrations (300 per task) across 40 tasks in five domains: home, hospital, kitchen, laboratory and sports, collected by 20 participants who each contributed 15 demonstrations per task, with gaze sampled at 300 Hz and an average trajectory length of 30.0 seconds. Table I in the paper lines this up against six prior robot-manipulation and gaze datasets: only two others (HARMONIC and DAA) record any gaze at all, both at 120 Hz against GazeAct's 300 Hz, and neither carries GazeAct's multi-view transfer.
At training time, the transferred gaze targets add a regularization term to the policy's visual attention, nudging a language-conditioned attention map toward the point a human actually looked at when executing that instruction. At inference, the model runs gaze-free: no eye tracker, no extra input stream, just the attention habit the regularizer left behind.
Table II's real-world evaluation runs 100 trials per task per method (50 standard condition, 50 under added visual and positional perturbation, both summed into the Overall column with 95% Wilson confidence intervals):
| Task | Standard: base → ours (/50) | Robustness: base → ours (/50) | Overall base [95% CI] | Overall ours [95% CI] | Gain |
|---|---|---|---|---|---|
| Pick cup, place on plate | 25 → 37 | 14 → 27 | 39% [30.0, 48.8] | 64% [54.2, 72.7] | +25 pp |
| Open rice cooker | 34 → 41 | 21 → 30 | 55% [45.3, 64.4] | 71% [61.5, 79.0] | +16 pp |
| Transfer tennis ball between containers | 9 → 19 | 6 → 9 | 15% [9.3, 23.3] | 28% [20.1, 37.5] | +13 pp |
| Arrange knife and fork in cutlery case | 14 → 20 | 8 → 15 | 22% [15.0, 31.1] | 35% [26.4, 44.7] | +13 pp |
| Place red pill in pill case | 24 → 30 | 17 → 24 | 41% [31.9, 50.8] | 54% [44.3, 63.4] | +13 pp |
| Hit nail on stand with hammer | 37 → 37 | 25 → 28 | 62% [52.2, 70.9] | 65% [55.3, 73.6] | +3 pp |
| Average across all 18 tasks | 27.9 → 33.4 (/50) | 20.2 → 25.2 (/50) | 48.1% [45.8, 50.4] | 58.6% [56.3, 60.8] | +10.5 pp |
The data pipeline turns one gaze reading, on one screen, into a consistent attention target for every camera the robot carries:
Two ablations, both on the same six-task subset, test whether the gain actually comes from gaze being real and gaze being soft.

What it means for teams adding gaze to a capture pipeline
The regularization-strength ablation is the result worth remembering before trying this: gaze helps at the paper's chosen weight (59.5% to 73.5% on the six-task subset) and actively hurts, 38.0% against a 59.5% no-gaze baseline, at the heaviest weight tested. A team that treats recorded gaze as ground truth to match exactly, rather than a soft prior to lean toward, is working against the paper's own result, not with it.
The source ablation separates two different claims that are easy to conflate: attention supervision of any kind helps (uniform and central-bias priors both move the baseline, 49.5% and 55.5% against the implicit no-prior baseline), and real human gaze helps more than a synthetic stand-in for it (73.5% for real gaze against 67.2% for a pseudo-gaze saliency model trained to imitate it). Both are true at once. Teams without a gaze-capture setup get a real, smaller gain from a cheap saliency heuristic; teams willing to add an eye tracker to teleoperation get more.
Eye tracking during screen-based teleoperation is a modest hardware add, nowhere near the cost of robot time itself, and it adds no cost at inference since the model runs gaze-free. The open question this paper does not answer is whether gaze recorded through a VR headset or AR glasses, rather than a flat screen, transfers the same way, since head-mounted eye tracking changes what counts as the gaze-source camera view.
Check it yourself
All five tables (dataset comparison, the 18-task real-world evaluation, both ablations, cross-architecture results and LIBERO-Spatial) are in the HTML build at https://arxiv.org/html/2610.24507v1. The 18-task average checks arithmetically from the per-task counts in Table II: summing the 'ours' overall success counts across all 18 tasks and dividing by 1,800 total trials reproduces 58.6%.
The paper's abstract page lists no linked code repository, dataset release or video as of 22 October 2026.
What would prove this wrong
Our claim: gaze's benefit here comes specifically from using a real, soft attention signal, not from any attention regularization in general, because the heaviest-weight ablation performs worse than no regularization at all (38.0% against 59.5%), while a synthetic attention prior recovers only part of the real-gaze gain (67.2% and 55.5% against 73.5%).
It is wrong if, by 1 July 2027, an independent replication finds a synthetic saliency prior matching or beating real recorded gaze on a task set GazeAct did not test, which would suggest the gap here reflects this paper's specific saliency model rather than a real ceiling on synthetic priors, or finds that a different regularization schedule (not the fixed weights tested here) removes the heavy-weight penalty entirely.