
Handheld Demonstrations Scored Zero on the Lift. Ten Teleoperated Episodes Took It to 70%.
DITTO puts handheld and teleoperated collection on one device: a 7-DOF thumb-to-index exoskeleton and a kinematically identical robot hand with 1:1 actuator mapping. On the same test tube uncapping task, 50 demonstrations and 250 epochs, handheld-only data matched every mixture on the rotating stage and failed the grasp-and-lift stage entirely. Ten teleoperated episodes took it to 70%, teleoperation alone added another 20 points. Force feedback cut ratchet interaction force from 14.8 N to 6.9 N. (arXiv:2609.19196, Columbia University, 16 September 2026.)
A Diffusion Policy trained on handheld demonstrations alone failed every trial of the retain-grasp-and-lift stage of test tube uncapping. Adding ten teleoperated episodes took it to 70%. Teleoperation alone added a further 20 percentage points. On the rotate-and-remove stage of the same task, with the same 50-demonstration budget and the same 250 epochs, handheld-only sat within about 5 points of every mixture. The device, the operator, the camera placement and the task were identical across conditions. The paper is DITTO, arXiv:2609.19196, posted 16 September 2026 by Joaquin Palacios, Katelyn Lee, Cheng Zhang, Zhanpeng He and Matei Ciocarlie at Columbia University.
That split is the useful result, and it is only legible because one device produced both datasets. Every previous comparison of in-the-wild capture against teleoperation changed the hardware at the same time as the paradigm, so the gap could always be blamed on the interface. Here it cannot.
The 1:1 actuator mapping is what lets the same hardware do both jobs
The leader is a motorised 7-DOF thumb-to-index exoskeleton, 430 g, about $900 in parts, built on Dynamixel XC330-T181 motors whose 181:1 gear ratio is low enough that an operator can backdrive them comfortably during capture. It takes about 20 seconds to don and 10 to doff. The follower is a robot hand with the same kinematic structure, 935 g, about $1500, on XM430 motors except the distal index PIP and thumb IP joints, which use smaller XC330-T288s.
Because each leader joint maps to exactly one follower joint, bilateral teleoperation reduces to per-joint loops with no task-space force mapping anywhere in the system. The leader commands follower positions; the follower's estimated motor torque is fed back to the leader through a deadband that zeroes anything below a threshold, so free-space motion renders nothing and contact renders the contact. The loop runs at 200 Hz over off-the-shelf U2D2 adapters, with joint torque limited to roughly 200 mA, about 0.08 Nm, for operator safety.
In handheld mode the exoskeleton is worn alone with a camera and a pose tracker attached. The camera sits where the follower hand's camera sits and is placed so only the exoskeleton appears in frame, not the operator's hand. That removes the visual embodiment gap without inpainting or any other post-processing, which is the usual cost of in-the-wild capture rigs.
Force feedback halved the interaction force and doubled the throughput
Eight subjects, none with prior hand-teleoperation experience, ran two tasks under three conditions: full DITTO, DITTO with bilateral force rendering disabled, and an ablation that removes the exoskeleton entirely and retargets 6-DOF fingertip trackers to the follower hand through inverse kinematics. Condition order was randomised by coin flip in a hierarchy that kept donning and doffing to a minimum.
On the mahjong tile task, subjects completed 36.6 flips in 60 seconds with DITTO, 27.2 with feedback off and 16.8 under fingertip retargeting. Every subject's best total came with DITTO, and all but one came with force rendering enabled. On the ratchet task, mean interaction force measured under the fixture was 6.9 N with DITTO against 13.0 N and 14.8 N, and 92.8% of DITTO's force samples fell below the 14.8 N reference against 64.8% and 56.7%. One-sided permutation tests separated DITTO from fingertip retargeting on every metric at p at most 0.023, and DITTO from the no-feedback ablation on both ratchet force metrics at p 0.012.
The no-feedback condition was the fastest on the ratchet, 22.4 s against 24.1 s, and applied nearly twice the force to get there. The authors read that as operators compensating for missing force awareness with aggression, and the failure data agrees: tiles flicked off the platform and force-torque sensor overloads occurred in 6 of 8 subjects and only ever under the two conditions without force feedback, including one subject whose trials hit 100 N or more.
| Task | Metric | DITTO | DITTO-NF, no force feedback | Fingertip retargeting | Source |
|---|---|---|---|---|---|
| Mahjong tile | flips in 60 s, higher better | 36.6 +/- 11.0 | 27.2 +/- 18.0 | 16.8 +/- 7.3 | arXiv:2609.19196 Table II |
| Ratchet | time for 3 revolutions, s | 24.1 +/- 6.6 | 22.4 +/- 9.1 | 34.2 +/- 8.1 | arXiv:2609.19196 Table II |
| Ratchet | interaction force, N | 6.9 +/- 2.0 | 13.0 +/- 3.0 | 14.8 +/- 2.5 | arXiv:2609.19196 Table II |
| Ratchet | share of samples at or below 14.8 N | 92.8% +/- 8.7 | 64.8% +/- 11.5 | 56.7% +/- 10.7 | arXiv:2609.19196 Table II |
| Both | trials lost to flick-off or sensor overload | none | occurred | occurred | arXiv:2609.19196 Section IV |
What a wearable exoskeleton cannot reach is an orientation problem, not a position problem
The authors put trakSTAR trackers on the index and thumb fingertips of seven subjects and recorded eight manipulation tasks, then downsampled the resulting tip-to-tip workspace with SE(3) farthest point sampling and asked, by inverse kinematics, which relative poses each exoskeleton design can reproduce. The tolerance is 1 mm in position and 20 degrees on the fingertip midline axis. Subject anthropometry spanned 27 mm of index finger length, 31 mm of palm width and 19 mm of thumb length.
DITTO reproduces at or near 1.0 of the sampled human poses on four of five tasks, with a mean axis error of 1.7 to 4.2 degrees. DexUMI-Xhand reaches at most 0.6 and DOGlove at most 0.5, with axis errors three to eight times larger. All three systems score near 1.0 on position alone, so the entire gap is orientation. A capture rig that gets the fingertip to the right place with the wrong approach angle records a different grasp from the one the operator intended.
Two things to hold against that table. The paper's conclusion summarises it as 96% coverage of the poses used by seven subjects across five tasks. And the comparison is kinematic throughout: it asks what each linkage could reach under a fixed tolerance, not what an operator wearing it actually recorded.
| Task | DITTO Succ. | DITTO X-Err | DexUMI-Xhand Succ. | DexUMI X-Err | DOGlove Succ. | DOGlove X-Err | Source |
|---|---|---|---|---|---|---|---|
| Ratchet | 1.0 | 4.2 | 0.1 | 32.1 | 0.5 | 12.1 | arXiv:2609.19196 Table III |
| Rubik's cube | 1.0 | 4.0 | 0.3 | 28.2 | 0.5 | 13.5 | arXiv:2609.19196 Table III |
| Test tube cap | 1.0 | 3.0 | 0.6 | 17.8 | 0.3 | 18.4 | arXiv:2609.19196 Table III |
| USB drive | 0.8 | 1.7 | 0.1 | 31.2 | 0.1 | 21.2 | arXiv:2609.19196 Table III |
| Mahjong tile | 1.0 | 3.4 | 0.2 | 30.6 | 0.2 | 18.6 | arXiv:2609.19196 Table III |
Policies trained on the teleoperated data, and the stage they still lose
Transformer Diffusion Policies with the relative pose representation from UMI clear most of the teleoperated tasks outright. Key rotation until the lock engages: 20 of 20 from 60 demonstrations. Mahjong flipping, two sequential rotations then a place into a box: 20 of 20 on both stages from 56 demonstrations. Bimanual Rubik's cube face rotations: 18 of 20 and 17 of 20 from 59 demonstrations.
USB insertion is the one that separates. Pick up the drive, 20 of 20. Extend the retractable body, 19 of 20. Insert it into the slot, 14 of 20. The failure concentrates on the stage requiring extrinsic contact reasoning against a fixed socket, which is the same class of stage that handheld data failed on the test tube task.

| Task | Demos | Epochs | Stage | Success | Source |
|---|---|---|---|---|---|
| Key rotation | 60 | 180 | Rotate key until lock engages | 20/20 | arXiv:2609.19196 Table IV |
| Mahjong flipping | 56 | 250 | Rotate twice | 20/20 | arXiv:2609.19196 Table IV |
| Mahjong flipping | 56 | 250 | Pick and place | 20/20 | arXiv:2609.19196 Table IV |
| USB insertion | 55 | 300 | Pick up USB | 20/20 | arXiv:2609.19196 Table IV |
| USB insertion | 55 | 300 | Extend USB | 19/20 | arXiv:2609.19196 Table IV |
| USB insertion | 55 | 300 | Insert into slot | 14/20 | arXiv:2609.19196 Table IV |
| Rubik's cube, bimanual | 59 | 300 | Rotate right face | 18/20 | arXiv:2609.19196 Table IV |
| Rubik's cube, bimanual | 59 | 300 | Rotate top face | 17/20 | arXiv:2609.19196 Table IV |
What this means if you are choosing a collection paradigm
Handheld capture and teleoperated capture are not two prices for the same commodity. They buy different stages of the same task. On uncapping, the finger-coordination stage was fully covered by handheld data and the grasp-and-lift stage was not covered at all. Any plan that quotes a per-hour rate for in-the-wild collection and compares it against a per-hour rate for teleoperation is comparing incomparable units until the task is decomposed into stages.
The authors' explanation is an action mismatch, and it is the mechanism worth designing against: in handheld mode the human applies the force and the human's own compliance stabilises the grasp, so the recording never contains a robot actuator doing that work. Teleoperated demonstrations contain robot-native contact. If a stage's success depends on how the actuator behaves under load, in-the-wild data does not carry it, no matter how many hours you buy.
Ten teleoperated episodes against fifty is the ratio to notice. A 20% teleoperated fraction recovered a stage that was at zero. That is a mixed-supply design, and it argues for keeping a small high-fidelity teleoperation capability rather than treating scale capture as a replacement for one. The authors put this the same way in their limitations: in-the-wild for pretraining at scale, teleoperation for behaviour alignment.
Two things the device does not do, stated by the authors. It is a two-finger system with no palmar surface, so whole-hand grasp taxonomies are out of scope. And it carries no tactile sensing at all, which means the force feedback an operator feels is inferred from motor current, not measured at the fingertip. For a capture rig aimed at contact-rich data, that is the gap to close next.
Check it yourself
The project page is live at ditto-robotics.github.io and the preprint is at arXiv:2609.19196, released under CC BY-NC-ND 4.0. Videos of the user study and the learned policies are on the project page. No CAD, firmware or dataset release is announced in the preprint, so the hardware claims are not yet independently rebuildable.
The workspace comparison is the part you can reproduce today without the device. The IK solver is named, mink, and the two comparison exoskeletons are public: DOGlove (RSS 2025) and the DexUMI-Xhand exoskeleton (CoRL 2025). Take your own tip-to-tip capture, downsample it with SE(3) farthest point sampling, and run each linkage against the same 1 mm and 20 degree tolerances. Changing the orientation tolerance from 20 degrees to 30 will move DexUMI's and DOGlove's numbers substantially, since their reported axis errors sit between 12 and 32 degrees.
For the mode comparison, the reproducible protocol is in Section VI-B: one unimanual task, 50 demonstrations, 250 epochs, Transformer Diffusion Policy, the same operator collecting both sources, and the task scored per stage rather than end to end. Scoring per stage is the part most collection audits skip, and it is where the entire finding lives.
Note what we could not read. The per-mixture success values for handheld and teleoperated data appear only in Figure 6 of the preprint, not in a table, so the numbers quoted here, 0%, 70%, and a further 20 points, are the ones the authors state in the running text of Section VI-B.
What would prove this wrong
The handheld failure rests on one task, one stage, and one policy architecture. Eight subjects ran the user study, but the data-mixture experiment is a single unimanual task with 50 demonstrations. Treat it as a strong anecdote about a mechanism, not as a measured rate.
Falsifiable, with a date: by 30 June 2027, if a policy trained on handheld-only DITTO data reaches 50% or better on a retain-grasp-and-lift stage of any task, using the same device and no teleoperated episodes at all, then the action-mismatch explanation is wrong and the zero was a data-volume artefact rather than a structural gap. A ten-fold increase in handheld episodes on the same task would settle it.
The second claim that could fail is the workspace one. Table III measures what each linkage can reach under a fixed tolerance, not what an operator wearing it actually recorded. If someone publishes measured tip-to-tip trajectories from DexUMI-Xhand or DOGlove during real manipulation and the achieved orientation spread exceeds what the IK analysis predicts, the 0.1 to 0.6 coverage numbers understate those devices, and the comparison would need redoing on recorded data rather than on kinematics.
Sources
- Palacios, Lee, Zhang, He and Ciocarlie, DITTO: Dexterous Interface for Transparent TeleOperation, arXiv:2609.19196, 16 September 2026
- arXiv HTML render, Tables II to IV, Figures 3 and 6, Sections III to VII
- DITTO project page, videos of the user study and learned policies
- Zhang, Hu, Yuan and Xu, DOGlove: Dexterous Manipulation with a Low-Cost Open-Source Haptic Force Feedback Glove, RSS 2025
- Xu et al., DexUMI: Using Human Hand as the Universal Manipulation Interface for Dexterous Manipulation, CoRL 2025
- Chi et al., Universal Manipulation Interface, the relative pose representation used by the policies
- BLO LAB, what teleoperation data is and what it costs
Building or training robots?
We license manipulation datasets and run custom capture programs. Get in touch to see what fits.

A Closed-Form Weight Edit Took pi0.5 From 27 to 106 of 128 on a Misread Instruction, but Only When Written Into the VLM

V-JEPA 2's Predictor Adds 0.04 Top-1 Over Copying the Present on 27,000 Egocentric Trials. By Horizon, It Runs From Minus 0.05 at 1 s to Plus 0.16 at 3.5 s.

